What is the Timer Node?
The Timer node pauses your Workflow for a set length of time before letting it continue. Unlike a plain delay, it can be reset before it finishes. If a defined "reset" event happens before the timer runs out, the countdown starts over. If the full duration passes with no reset, the Workflow continues.

Think of it as a dead-man's switch: it only fires if nothing resets it in time.
When Should I Use It?
The Timer node is useful whenever you need your Workflow to react to something not happening within a given window, rather than something that did happen. Common examples include:
- Alerting if an asset hasn't reported in within an expected window.
- Waiting a fixed period after an event before proceeding, but cancelling that wait if a follow-up event arrives first.
- Building in a "cooldown" that restarts every time the same event repeats, only progressing once the events stop.
Why Does It Matter?
Some situations are only worth flagging once they've gone quiet for a while, not the moment they start. The Timer node lets your Workflow tell the difference between "this is still actively happening" (the reset keeps firing) and "this has stopped or gone silent" (the timer runs out uninterrupted). That distinction helps you catch real gaps or lapses without reacting to normal, ongoing activity.
How Do I Use It?
- Drag the Timer node from the right-hand column onto the canvas, and place it after the event that should start the countdown.
- Hover over the node and select edit to configure it.
- Set the Event Duration and choose its Unit: seconds, minutes, or hours.
- Set the Date/Time Source the countdown should anchor to, such as Event Time.
- Under Start Filters, define the event(s) that begin the countdown.
- Under Reset Filters, define the event(s) that should restart the countdown if they occur before it completes.
- Connect the green ball to continue your Workflow once the full duration has elapsed without a reset.

Note: If you leave Reset Filters empty, the Timer behaves as a plain fixed delay. It will always run its full duration regardless of what else happens.
Common Pitfalls
- Confusing Timer with Duration: Duration measures how long a condition stays true. Timer counts down a fixed period and can be reset by a separate event. Use whichever matches what you're actually trying to catch.
- No reset filter when one is needed: without it, the Timer can't tell an ongoing situation from a one-off, and may fire (or fail to fire) unexpectedly.
- Mismatched units: an easy slip between seconds, minutes, and hours, especially when copying settings between Workflows.
- Listener node not configured correctly: the Timer node can only start counting once the right event makes it through the Listener node.
Related Articles
Still Need Help?
Contact our Support team. We are always happy to help.